Radar level gauges GQ Radar

General information

Radar level gauges GQ Radar

Engineering company Quantor JSC presents high-tech liquid and bulk product level measuring devices on the Russian and Kazakh markets!

The principle of operation of the level gauges is based on the frequency method of distance measurements using a frequency-modulated continuous wave radar (FMCW). The radar sends a high-frequency signal, the frequency of which increases linearly. The emitted signal is reflected from the surface of the measured medium and is received by the antenna as an echo signal with a changed frequency. In the electronic module of the level sensor, the difference between the frequencies of the reflected and emitted signals at the current time is determined, which is directly proportional to the distance to the surface of the measured medium.

The level gauges consist of an electronic module, a radar and an antenna located in the body of the level gauge, a connecting fitting or a flange. The electronic module can be equipped with a digital indicator.

The level gauges are manufactured in general industrial or explosion-proof (explosion-proof shell [Ex d] and/or intrinsically safe circuit [Ex ia]) versions, in two series that differ in operating frequency:

  • 6x – operating frequency 26 GHz;

  • 8x – operating frequency 76-81 GHz.

The 6x series includes models GQ Radar 61, GQ Radar 62, GQ Radar 63, GQ Radar 64, GQ Radar 65, GQ Radar 66, GQ Radar 67, 8x series – models GQ Radar 80, GQ Radar 80S, GQ Radar 81, GQ Radar 81S, which differ from each other in the measuring range and limits of permissible error.

The equipment is adapted for operation at ambient temperatures from -60 °C to + 60 °C, meets the requirements of GOST standards and has certificates:

  • Certificate of conformity to the Technical Regulations of Customs Union "On the safety of equipment for work in explosive atmospheres" (TR CU 012/2011);

  • Pattern Approval Certificate of Measuring Instruments and certified verification procedure;

  • Declaration of conformity to Technical Regulations 004/2011);

  • Declaration of conformity to Technical Regulations of the Customs Union "Electromagnetic Compatibility" (TR CU 020/2011).

The level gauges are sold under the brand name "GQ".

Images

GQ Radar 61, GQ Radar 62, GQ Radar 63, GQ Radar 64:

GQ Radar 65, GQ Radar 66, GQ Radar 67:

GQ Radar 80, GQ Radar 80S, GQ Radar 81, GQ Radar 81S:

Technical and metrological characteristics of level gauges

The name, characteristics

Value

Measuring range of the distance to the product surface (level), m:

– GQ Radar 61, GQ Radar 66, GQ Radar 67

– GQ Radar 62, GQ Radar 63, GQ Radar 64, GQ Radar 65

– GQ Radar 80S, GQ Radar 81S

– GQ Radar 80, GQ Radar 81

from 0,5 to 20

from 0,3 to 70

from 0,08 to 20

from 0,08 to 100

Limits of the permissible absolute error of measuring the distance to the product surface (level) by a digital indicator or digital output signal, mm:

– GQ Radar 61, GQ Radar 65, GQ Radar 67

– GQ Radar 62, GQ Radar 66

– GQ Radar 63, GQ Radar 64

– GQ Radar 80S, GQ Radar 81S

– GQ Radar 80, GQ Radar 81 at Lmeas ≤ 30000 mm

– GQ Radar 80, GQ Radar 81 at Lmeas > 30000 mm

±5

±3

±15

±1, ±3

±1, ±3

±3

Limits of the permissible reduced error of reproduction of the output current signal from 4 to 20 mA, % of the reproduction range:

– main

– additional, caused by a change in the ambient temperature from the temperature (20 ± 10) °C for every 10 °C

±0,03

±0,005

Electrical output signals

from 4 to 20 mA, HART, ModBus RTU (RS-485)

Electrical power supply parameters:

– DC voltage, V

– AC voltage, V

– rated frequency of alternating current, Hz

from 15 to 28

from 190 to 250

50

Resolution of digital indicator and digital output signal, mm

0,01

Operating conditions:

– ambient temperature, °С

– relative humidity (at a temperature of +40 °C), %, no more

from -60 to +60

95

Parameters of the measured medium:

– overpressure, MPa

– temperature, °С

from -0,1 to 2

from -40 to +350

Overall dimensions of the body of the level gauges, mm, no more:

– length

– width

– height

121

97

164

The weight of the body of the level gauges, kg, no more

1,74

Average service life, years, at least

13

Average time to failure, h, at least

110 000

The use of radar level gauges on Customers facilities

Documentation

Каталог

Опросный лист

Описание типа СИ

Методика поверки

Сертификат Соотвествия Exd ТР ТС 012 О безопасности оборудования для работы во взрывоопасных средах

Сертификат Соотвествия Exi ТР ТС 012 О безопасности оборудования для работы во взрывоопасных средах

Декларация соотвествия ТР ТС 004 Таможенного союза О безопасности низковольтного оборудования

Декларация соответствия ТР ТС 020 Электромагнитная совместимость технических средств

Сертификат безопасности уровень SIL 2

Customer Reviews